CHLORINE, CYANURIC ACID AND pH PHOTOMETER
Legionella species is the agent that causes human Legionnaires’ disease as well as the lesser form, Pontiac Fever. Transmission is facilitated by the inhalation of mist droplets containing the Legionella bacteria. Common sources of Legionella include cooling towers used in industrial cooling water systems as well as in large central air conditioning systems, domestic hot water systems, fountains, and similar disseminators that draw from a public water supply. Natural sources include freshwater ponds and creeks. Since Legionella is especially harmful to people with weakened immune systems, Legionella should be actively checked for in the water systems of hospitals and nursing homes. The HI 96725 measures 4 parameters that are crucial in monitoring for preventive maintenance or disinfection.
Order Information:
HI 96725 is supplied with (2) sample cuvettes with caps, 9V battery and instructions. CAL CHECK™ standards and reagents sold separately.
Specifications
| Range | Free Chlorine: 0.00 to 5.00 mg/L; Total Chlorine: 0.00 to 5.00 mg/L (ppm); Cyanuric Acid: 0 to 80 mg/L (ppm); pH: 6.5 to 8.5 pH | |
| Resolution | Chlorine: 0.01 mg/L (ppm); Cyanuric Acid: 1 mg/L (ppm); pH: 0.1 pH | |
| Precision | Chlorine: ±0.03 mg/L (ppm) ±3% of reading; Cyanuric Acid: ±1 mg/L (ppm) ±15% of reading; pH: ±0.1 pH | |
| Light Source | Tungsten lamp | |
| Light Detector | Silicon photocell with narrow band interference filter @ 525 nm | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Power Supply | (1) 9V battery | |
| Auto-off | After 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode | |
| Dimensions | 192 x 102 x 67 mm (7.6 x 4 x 2.6”) | |
| Weight | 290 g (10 oz.) | |
| Method | Chlorine:Adaptation of the EPA recommended DPD method 330.5 ; Cyanuric Acid: Adaptation of the Turbidimetric method; pH: Phenol red method |
| Reagents & Standards | |
| HI 95701-11 | Cal Check® Standard Cuvet Kit for HI 95701 |
| HI 93701-01 | Chlorine, free, DPD Method (100 Tests) |
| HI 93701-03 | Chlorine, free, DPD Method (300 Tests) |
| HI 93701-F | Chlorine, free, DPD Method (300 Tests) |
| HI 93701-T | Chlorine, total, DPD Method (300 Tests) |
| HI 96710-11 | CAL CHECK™ standard cuvettes (pH) |
| HI 93710-01 | pH, Phenol Red Method (100 Tests) |
| HI 93710-03 | pH, Phenol Red Method (300 Tests) |
| HI 95711-11 | Cal Check® Standard cuvet for HI 95711 |
| HI 93711-01 | Chlorine, Total, DPD Method (100 Tests) |
| HI 93711-03 | Chlorine, Total, DPD Method (300 Tests) |
| HI 96722-11 | CAL CHECK™ standard cuvettes (CYS) |
| HI 93722-01 | Cyanuric Acid, Turbidimetric Method (100 Tests) |
| HI 93722-03 | Cyanuric Acid, Turbidimetric Method (300 Tests) |