HI 83213
Monitor Municipal Wastewater
HI 83213 is a multi-parameter instrument that can also run on common 9V batteries to measure 24 of the most important chemicals and metals in municipal wastewater.
• Microprocessor accuracy and touch-button convenience
• Only 6 keys to perform all measurements
• Can be transported anywhere: can run on battery power
• 24 different meters and test kits packaged into one handy meter
• Large LCD with self-diagnostic messages
• Built-in RS232 port to download to your PC
• For spare reagent see our reagent section
Order Information:
HI 83213 is supplied with 3 cuvets, bottle for D.O. test, batteries, 12 Vdc adapter and instructions.
Specifications
Light Source | 4 tungsten lamps with narrow band interference filter 420/525/575/610 nm | |
Light Detection | 4 silicon Photocells | |
Power Supply | 2 x 9V battery or 12 Vdc adapter | |
Auto Shut-off | after 10 minutes of non-use | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Dimensions | 230 x 165 x 70 mm | |
Weight | 640 g |
Multi Parameter Specifications
Parameter | Range | Method | Reagent Code |
---|---|---|---|
Aluminum | 0.00 to 1.00 mg/L | Aluminon | HI 93712-01 |
Ammonia LR | 0.00 to 3.00 mg/L | Nessler | HI 93700-01 |
Ammonia MR | 0.00 to 10.00 mg/L | Nessler | HI 93715-01 |
Bromine | 0.00 to 8.00 mg/L | DPD | HI 93716-01 |
Chlorine, free | 0.00 to 2.50 mg/L | DPD | HI 93701-01 |
Chlorine, total | 0.00 to 3.50 mg/L | DPD | HI 93711-01 |
Chromium VI HR | 0 to 1000 µg/L | Diphenylcarbohydrazine | HI 93723-01 |
Chromium VI LR | 0 to 300 µg/L | Diphenylcarbohydrazine | HI 93749-01 |
Color | 0 to 500 PCU | Platinum Cobalt | N/A |
Copper HR | 0.00 to 5.00 mg/L | Bicinchoninate | HI 93702-01 |
Copper LR | 0 to 1000 µg/L | Bicinchoninate | HI 95747-01 |
Iodine | 0.0 to 12.5 mg/L | DPD | HI 93718-01 |
Nickel HR | 0.00 to 7.00 g/L | Photometric | HI 93726-01 |
Nickel LR | 0.000 to 1.000 mg/L | PAN | HI 93740-01 |
Nitrate | 0.0 to 30.0 mg/L | Cadmium reduction | HI 93728-01 |
Nitrite HR | 0 to 150 mg/L | Ferrous sulfate | HI 93708-01 |
Nitrite LR | 0.00 to 0.35 mg/L | Diazotation | HI 93707-01 |
Oxygen, dissolved | 0.0 to 10.0 mg/L | Winkler | HI 93732-01 |
pH | 6.5 to 8.5 pH | Phenol red | HI 93710-01 |
Phosphate HR | 0.0 to 30.0 mg/L | Amino acid | HI 93717-01 |
Phosphate LR | 0.00 to 2.50 mg/L | Ascorbic acid | HI 93713-01 |
Phosphorus | 0.0 to 15.0 mg/L | Amino acid | HI 93706-01 |
Silver | 0.000 to 1.000 mg/L | PAN | HI 93737-01 |
Zinc | 0.00 to 3.00 mg/L | Zincon | HI 93731-01 |
Reagents & Standards | |
---|---|
HI 93712-01 | Aluminium, Aluminon Method (100 Tests) |
HI 93700-01 | Ammonia LR, Nessler Method (100 Tests) |
HI 93715-01 | Ammonia MR, Nessler Method (100 Tests) |
HI 93716-01 | Bromine, DPD Method (100 Tests) |
HI 93701-01 | Chlorine, free, DPD Method (100 Tests) |
HI 93711-01 | Chlorine, Total, DPD Method (100 Tests) |
HI 93723-01 | Chromium VI HR, Diphenylcarbohydrazide Method (100 Tests) |
HI 93749-01 | Chromium VI LR, Diphenylcarbohydrazide Method (100 Tests) |
HI 93702-01 | Copper HR, bicichoninate acid method (100 Tests) |
HI 93718-01 | Iodine, DPD Method (100 Tests) |
HI 93726-01 | Nickel HR, Photometric Method (100 Tests) |
HI 93740-01 | Nickel LR, PAN Method (100 Tests) |
HI 93728-01 | Nitrate, Cadmium Reduction Method (100 Tests) |
HI 93708-01 | Nitrite HR, ferrous sulphate method (100 Tests) |
HI 93707-01 | Nitrite LR, diazotization method (100 Tests) |
HI 93732-01 | Dissolved Oxygen, Winkler Method |
HI 93710-01 | pH, Phenol Red Method (100 Tests) |
HI 93717-01 | Phosphate HR, Amino Acid Method (100 Tests) |
HI 93713-01 | Phosphate LR, Ascorbic Acid Method (100 Tests) |
HI 93706-01 | Phosphorous, amino acid method (100 Tests) |
HI 93737-01 | Silver, Pan Method (100 Tests) |
HI 93731-01 | Zinc, Zincon Method (100 Tests) |
ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์ |