อุปกรณ์วัด Turbidity (Turbidity Benchtop Meter, ISO)

HI 88713

Turbidity Benchtop Meter, ISO

  • Graphic display, backlit LCD
  • Two, three, four or five point calibration
  • GLP features
  • Log up to 200 records
  • Contextual help and tutorial mode
  • USB PC connectivity

The HI 88713 turbidity bench meter meets and exceeds the requirements of the
ISO 7027 standard.

HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.

Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.

The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.

The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.

Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Order Information:
HI 88713-01 (115V) and HI 88713-02 (230V) are supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.

Specifications

RangeFNU Mode0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FNU Mode10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ratio Mode0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
ResolutionFNU Mode0.01; 0.1; 1 FNU
FNU Mode0.1; 1 FAU
NTU Ratio Mode0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ratio Mode0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
Accuracy @25°CFNU Mode±2% of reading plus stray light
FNU Mode±10% of reading
NTU Ratio Mode±2% of reading plus stray light / ±5% of reading above 1000 NTU
NTU Non-Ratio Mode±2% of reading plus stray light
Range Selectionautomatic
Repeatability±1% of reading or stray light, whichever is greater
Stray Light< 0.1 NTU (0.05 EBC)
Light Detectorsilicon photocell
Light SourceIR LED
MethodISO 7027 Method
Measuring Modenormal, average, continuous.
Turbidity Standards<0.1, 15, 100, 750 FNU and 2000 NTU
Calibrationtwo, three, four or five-point calibration
Log Memory200 records
PC InterfaceUSB
Environment0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply12 Vdc power input
Dimensions / Weight230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<

Related Articles

Latest Articles

PRODUCTS

Contact Us