อุปกรณ์วัด Turbidity (Precision Turbidity Benchtop Meter, EPA Compliant)

HI 88703

Precision Turbidity Benchtop Meter, EPA Compliant

  • Two measuring ranges: Ratio turbidity, non-ratio turbidity
  • Meets USEPA requirements
  • GLP features        
  • Two, three, four or five point turbidity calibration
  • USB PC connectivity
  • Log up to 200 measurements
  • Contextual help and tutorial mode

The HI 88703 turbidity benchtop meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.

This instrument has an EPA compliance reading mode which rounds the reading
to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration could be performed by using the supplied standards. When user prepared standards are used, calibration points can be modified.
H 88703 features complete GLP (Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked.

Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Order Information:
HI 88703-01 (115V) and HI 88703-02 (230V) is supplied with sample cuvettes and caps (5), calibration cuvettes, silicone oil (HI 93703-58), tissue for wiping cuvettes, power cord and instruction manual.

Specifications

RangeNon Ratio Mode0.00 to 9.99; 10.0 to 40.0 NTU;
0.0 to 99.9; 100 to 268 Nephelos
0.00 to 9.80 EBC
Ratio Mode0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU
0.0 to 99.9; 100 to 26800 Nephelos
0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
ResolutionNon Ratio Mode0.01; 0.1 NTU 0.1; 1 Nephelos; 0.01 EBC
Ratio Mode0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC
Range Selectionautomatic
Accuracy @25°C±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC)
±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC)
Repeatability±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC)whichever is greater
Stray Light< 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Light Detectorsilicon photocell
MethodNephelometric method (90°) or Ratio Nephelometric Method(90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B.
Measuring Modenormal, average, continuous
Turbidity Standards<0.1, 15, 100, 750 and 2000 NTU
Calibrationtwo, three, four or five-point calibration
Light Source/Lifetungsten filament lamp / greater than 100,000 readings
Display40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory200 records
PC InterfaceUSB
Environment0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply230 V/50 Hz or 115 V/60 Hz 20 W; auto-off after 15 minutes of non-use
Dimensions230 x 200 x 145 mm (9 x 7.9 x 5.7”)
Weight2.5 Kg (88 oz.)

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<

Related Articles

Latest Articles

PRODUCTS

Contact Us