HI 83749

Portable Turbidity Meter and Bentonite Monitoring

  • GLP Features
  • Fast Tracker™ with iButton™ tags    
  • Continuous measurement mode; Verifies the settling rate of suspended matter.
  • Signal Average (AVG) mode; Accumulates multiple readings giving a final average value.
  • Backlit LCD
  • USB

Wines with low phenol contents, such as rosé, light reds and whites should be checked for protein stability before bottling. HANNA is offers a quick test to verify the risk of future protein haze formation. If protein instability is detected, a subsequent test can help define the right amount of bentonite to be added for improving protein stability. It is important not to overdose bentonite to avoid stripping wine flavor, body, and significant loss of color, especially in young red wines. Moreover, adding only the necessary amount of bentonite to obtain the desired protein stability also saves costs.

The HI 83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. In the USEPA measurement mode the instrument rounds the readings to meet USEPA reporting requirements.

Order Information:
HI 83749-01 (115V), HI 83749-02 (230V) and HI 83749-03 (AUS plug) are supplied with sample cuvettes and caps (6), calibration cuvettes (HI 83749-11) (4), bentocheck reagent (HI 83749-0) and silicone oil (HI 93703-58), 1000 µL automatic pipette with two tips and instructions sheet, 25 mL glass vials with caps (4), 1 mL syringe with two tips, funnel, filter paper (25), cuvette cleaning cloth, 12 VDC adapter, batteries, instructions and rugged carrying case.

Specifications

Range0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1200 NTU automatic range selection
Resolution0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1200 NTU
Accuracy @25°C   ±2% of reading plus 0.05 NTU
Accuracy @25°C±2% of reading plus 0.05 NTU
Repeatability  ±1% of reading plus 0.05 NTU
Stray Light< 0.05 NTU
Light Sourcetungsten filament lamp
Light Detectorsilicon photocell
Method  Ratio Nephelometric
Calibrationtwo, three or four points
Log Memory200 records
PC ConnectivityRS232 or USB 1.1
Environment0 to 50°C; max 95% RH non-condensing
Power Supply1.5V AA batteries (4) / 12 VDC adapter
Auto-offafter 15 minutes of non-use
Dimensions / Weight224 x 87 x 77 mm (8.7 x 3.3 x 3.1″) / 512 g (17.6 oz.)

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<

Related Articles

Latest Articles

PRODUCTS

Contact Us