อุปกรณ์วัด pH (Calibration Check™ Portable pH/ORP Meter)

HI 9126

Calibration Check™ Portable pH/ORP Meter
The HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.

Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point.  Users can easily determine if readings are taken too far outside the calibration range.

The HI 9126 can store and recall readings at the touch of a button.

HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.

Specifications
Range  pH  -2.00 to 16.00 pH
ORP  ±699.9 mV; ±1999 mV
Temperature  -20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution  pH  0.01 pH
ORP  0.1 mV; 1 mV
Temperature  0.1°C / 0.1 °F
Accuracy @ 20°C  pH  ±0.01 pH
ORP  ±0.2 mV; ±1 mV
Temperature  ±0.4°C/±0.8°F (excluding probe error)
pH Calibration
Check  yes, check of the electrode status during calibration
Calibration  pH  automatic, one or two point with seven memorized buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
Offset  ±1 pH
Slope  from 80 to 108%
Temperature
Compensation  automatic or manual, -20 to 120°C (-4 to 248°F) without temperature probe
pH Electrode  HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe  HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Input Impedance  1012 Ohms
Battery Type / Life  1.5V (3) AAA / approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)
Environment  0 to 50°C (32 to 122°F); RH max 100%
Dimensions  185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight  300 g (10.6 oz.)

Accessories 
Electrodes
HI 1230B  Combination pH Electrode, for Field Applications
BNC Connection
HI 3230B  ORP Electrode for Municipal Water and Quality Control
BNC Connection
Solutions
HI 5004L  pH 4.01 buffer solution
HI 5007L  pH 7.01 buffer solution
HI 5010L  pH 10.01 buffer solution
HI 70300L  Electrode Storage Solution
1 x 500 mL bottle
HI 7061L  General Purpose Cleaning Solution
1 x 500 mL bottle
Probes
HI 7662  Stainless Steel Temperature Probe

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<

Related Articles

Latest Articles

PRODUCTS

Contact Us