pH/ORP/ISE Graphic LCD pH Benchtop Meter
HANNA’s HI 3221 benchtop instrument features up to five point pH calibration with a choice of five custom buffers and seven standard buffers.

HI 3221 features an interactive user support interface that assists you before, during and after measurement. On-screen tutorials guide users through set-up, calibration and measurement while context sensitive help of any screen is available at a push of a button. The help screen includes language specific assistance for menu parameters, calibration, logging, contact and accessory information for your instrument.

This instrument features HANNA’s exclusive Calibration Check™, a diagnostics system that ensures accurate pH readings every time. By alerting users of potential problems during the calibration process, the Calibration Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration. Throughout the calibration process, users are guided step-by-step by the on-screen tutorial. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.

The HI 3221 is equipped with one input channel.

This instrument can measure using ORP electrodes (pH channel input), thanks to it’s capability to measure mV with a resolution up to 0.1 mV. The HI 3221 can use ISE electrodes in the ppm scale (pH channel input) and provides a choice of measurement units (ppb, ppm, molarity, weight/volume %).

Specifications
Range pH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
mV ±2000 mV
ISE 1.00 E-3 to 1.00 E5 concentration
Temperature -20.0 to 120.0 °C (-4.0 to 248.0°F)
Resolution pH 0.1; 0.01; 0.001 pH
mV 0.1 mV
ISE 3 digits 0.01; 0.1; 1; 10 concentration
Temperature 0.1°C (0.1°F)
Accuracy
(@ 20ºC/68ºF) pH ±0.01; ±0.002 pH
mV ±0.2 mV
ISE ±0.5% of reading (monovalent ions),
±1% of reading (divalent ions)
Temperature ±0.2°C (±0.4°F) (excluding probe error)
Calibration pH up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers
ISE up to two point calibration, six standard solutions
(0.1, 1, 10, 100, 1000, 10000 ppm)
Slope from 80 to 110%
pH Calibration Check™  yes
Rel. mV Offset Range  ±2000 mV
pH Temp. Compensation  manual or automatic from -20.0 to 120.0°C
(-4.0 to 248.0°F)
Input Channels  1
pH Electrode  HI 1131B pH electrode with glass body, BNC connector and 1 m (3.3’) cable (included)
Temperature Probe  HI 7662-T temperature probe, stainless steel with 1 m (3.3’) cable (included)
Logging  log on demand 300 samples
Lot Logging  5, 10, 30 seconds; 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes (max 600 samples)
PC Connectivity  opto-isolated USB (with optional HI 92000 software)
Input Impedance  1012 ohm
Power Supply  12 VDC adapter (included)
Environment  0-50°C (32 to 122°F) RH max 55% non-condensing
Dimensions  235 x 207 x 110 mm (9.2 x 8.14 x 4.33”)
Weight  1.8 kg (4.1 lbs.)

Accessories
Solutions
HI 5004L  pH 4.01 buffer solution
HI 5007L  pH 7.01 buffer solution
HI 5010L  pH 10.01 buffer solution
HI 7020L  ORP Test Solution at 200/275 mV (@20°C)
1 x 500 mL bottle
HI 7021L  ORP Test Solution at (240 mV @ 25°C/77°F)
1 x 500 mL bottle
HI 7022L  ORP Test Solution at 470 mV @ 25°C/77°F)
1 x 500 mL bottle
HI 7091L  Reducing Pretreatment Solution
1 x 500 mL bottle
HI 7092L  Oxidizing Pretreatment Solution
1 x 500 mL bottle
HI 7071  Electrolyte Solution, 3.5M KCl + AgCl
4 x 30 mL bottles
HI 7082  Electrolyte Solution, 3.5M KCl
4 x 30 mL bottle
HI 7061L  General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L  Electrode Storage Solution
1 x 500 mL bottle
Accessories
HI 92000  Windows® Compatible Software
HI 920013  USB Cable
HI 76404N  Electrode Holder for HI 42xx Type Bench Meters

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<

Related Articles

Latest Articles

PRODUCTS

Contact Us