HI 2400 Dissolved Oxygen Laboratory Bench Meter HI 2400 is a dissolved oxygen benchtop meter with automatic calibration and % or mg/L (ppm) measurement range. The measurement is automatically compensated for altitude and salinity compensation based on the user settings for altitude up to 4000 m and 40 g/L for salinity. Calibration is performed at one or two points at 0% using HANNA’s HI 7040 solution or 100% in air. Measurements are automatically temperature compensated by using the polarographic DO probe with built-in temperature sensor. This probe features screw cap membranes for easy replacement. With a built-in logging function, measurements are stored in non volatile memory, and can be transferred to a PC through the USB port using the optional HI 92000 software and HI 920013 USB cable. The software is provided with an exclusive online guide of all the commands available and allows data printing, plotting and exporting. The 8000 record logging interval allows the possibility of process and experimental monitoring of DO. The logging interval is automatic with user selectable intervals from 5 seconds to 180 minutes according with the speed of DO variation inside the process. The HI 2400 also provides users with GLP (Good Laboratory Practice) capabilities. GLP is a set of functions that allow the storage and retrieval of data regarding calibration. The GLP feature provides data consistency and a calibration reminder which can be set to alert the user that too much time has elapsed since the last calibration and a new one should be performed. Order Information: HI 2400-01 (115V) and HI 2400-02 (230V) are supplied with HI 76407/2 dissolved oxygen probe, HI 76407A membrane caps (2), HI 7041S electrolyte solution (30 mL), 12 VDC adapter and instructions. Specifications Range DO 0.00 to 45.00 mg/L % Saturation O2 0.0 to 300.0% Temperature 0.0 to 50.0°C Resolution DO 0.01 mg/L % Saturation O2 0.1% Temperature 0.1°C Accuracy (@20°C) DO ±1.5% F.S. % Saturation O2 ±1.5% F.S. Temperature ±0.2°C (excluding probe error) DO Calibration one or two points at 0% (HI 7040 solution) and 100% (in air) Altitude Compensation 0 to 4000 m (resolution 100 m) Salinity Compensation 0 to 40 g/L (resolution 1 g/L) Temperature Compensation automatic, 0.0 to 50.0°C (32.0 to 122ºF) Probe HI 76407/2 polarographic DO probe with internal temperature sensor, DIN connector and 2 m (6.6’) cable (included) Logging Interval 5, 10, 30 seconds or 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes PC Connection opto-isolated USB Power Supply 12 VDC adapter Environment 0 to 50°C (32 to 122°F); RH max 95% Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) Weight 1.3 kg (2.9 lbs.) Accessories Solutions HI 7040L Zero Oxygen Solution HI 7041S Refilling Electrolyte Solution, 30 mL HI 7041M Refilling Electrolyte Solution, 230 mL HI 7041L Refilling Electrolyte Solution, 500 mL Accessories HI 76407A/P Membranes for DO Probes HI 92000 Windows® Compatible Software HI 920010 Cable for PC Connection, 9 to 9-pin Probes HI 76407/2 Standard DO Probe, 2 m cable HI 76407/4 Standard DO Probe, 4 m cable HI 76407/10 Standard DO Probe, 10 m cable HI 76407/20 Standard DO Probe, 20 m cable HI 76408 Thinner Lighter DO Probe for Laboratories |
ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์ |
อุปกรณ์วัด ออกซิเจนละลาย (Dissolved Oxygen Laboratory Bench Meter)
สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า
บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
E-mail : info@highents.com
IDline : @alltestkit