วันเสาร์, กันยายน 30, 2023

Leveraging Thai Scientific
Invention To Global Commercialization

อุปกรณ์วัดฟลูออไรด์ (Checker®HC Handheld Colorimeter – Fluoride Low Range)

HI 729

Checker®HC Handheld Colorimeter – Fluoride Low Range

  • Easier to use and more accurate than chemical test kits
    SPADNS method
    ±0.05 ppm ±5% of reading accuracy
    Large, easy to read digits
    Auto shut off
  • Dedicated to a single parameter
    Designed to work with HANNA’s reagents
    Uses 10 mL glass cuvettes
  • Small size, big convenience
    Weighing a mere 64 g (2.25 oz.), the Checker®HC
    easily fits into the palm of your hand or pocket
    Use for quick and accurate on the spot analysis
    Single button operation: zero and measure
    Operated by a single AAA battery
  • Ideal for water quality

Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.

A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.

The HI 729 Checker®HC is simple to use. For this measurement you need 2 vials (#1 and #2); in both vials add 2 mL of reagent and until the mark: deionized water in vial #1 and sample in vial #2, and gently invert 5 times, and wait 2 minutes. Then insert the cuvette #1 into the HI 729 Checker®HC and press the button to zero; after that cuvette #2 to read the measurement results.

Order Information:
HI 729 Checker®HC is supplied with sample cuvettes with caps (2), reagents for 6 tests, syringe with tip, battery and instructions.

 Specifications

Range0.00 to 2.00 ppm
Resolution0.01 ppm
Accuracy @ 25°C±0.05 ppm ±5% of reading
Light SourceLED @ 575 nm
Light Detectorsilicon photocell
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type(1) 1.5V AAA
Auto-offafter two minutes of non-use and ten seconds after reading
Dimensions81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight64 g (2.25 oz.)
Method  adaptation of SPADNS method

สอบถามรายละเอียดเพิ่มเติม ขอใบเสนอราคา สั่งซื้อสินค้า

บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1
ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929
คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653
IDline : @alltestkit

>> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<